Juist met Stroom

AIO-LFP 6.14-24.5 kWh

4-12kW Three Phase lnverter

  • Remote Monitoring
  • SOC Dynamic Calibration
  • Battery Integration Strategy
  • Parallel Connection
  • Triple Electrical Safety Protection
  • Voltage Balancing Between the Batteries
  • Accurate Acquisition of Battery’s Information
  • ON/OFF Management Including Automatic Wake-up Function
  • Module design, Scalable up to 4 Battery Packs(6.14 kWh, 512V module)

92%-98%

Discharge efficiency rates range from 92% to 98% (compare with low voltage three phase inverter system)

<30w

Anti-reflux power accuracy is less than 30W

< lSw

Self-consumption of the inverter power and stand-by less than lSW

<25dB

Noise is less than 25d8 at full power

>97%

Useable energy of battery is over 97%

< 2 Hours

lnstallation is less than 2 hours

>99%

Aftersales contentment of APP&Web is over 99%

130-700v

Battery input of inverter l30V-700V

Specifications

Model Uhome-INVT-3P-4kW Uhome-INVT-5P-5kW Uhome-INVT-3P-6kW Uhome-INVT-5P-8kW Uhome-INVT-3P-10kW Uhome-INVT-3P-12kW
Input (DC)
Max DC Power 6000W 7500W 9000W 12000W 15000W 15000W
Max DC Voltage 1000 Vdc
MPPT Voltage Range 200…850 Vdc
Max Input Current per String 13A
Number of MPP Trackers 2
Number of Input Strings 2
Battery Input
Battery Type Li-Ion
Battery Voltage Range 130-700V
Max Charge/Discharge Current 25A / 25A
Charge Strategy Self-adaption to BMS
Output (AC) – Grid
AC Nominal Power 4000 VA 5000 VA 6000 VA 8000 VA 10000 VA 12000 VA
Max AC Apparent Power 5000 VA 5500 VA 7000 VA 8800 VA 11000 VA 13200 VA
Max Output Current 8A 10A 12A 15A 17A 20A
Nominal AC Output 50/60Hz; 400/350V
AC Output Range 45/55Hz; 280-490 Vac (Adj)
Power Factor 0.8 leading – 0.8 lagging
Harmonics (THD) < 3%
Grid Type 3W/N/PE
Three-Phase Unbalance 0~100% 0~80%
Output (AC) – Backup
Max AC Apparent Power (Backup) 4000 VA 5000 VA 6000 VA 8000 VA 10000 VA 10000 VA
Nominal Output Voltage 400/380V
Nominal Output Frequency 50/60Hz
Output THDV (@Linear Load) < 3%
Efficiency
Max Conversion Efficiency 98.0% 98.0% 98.2% 98.2% 98.2% 98.2%
European Efficiency 97.3% 97.3% 97.5% 97.5% 97.5% 97.5%
Max Battery to AC Efficiency 97.2% 97.2% 97.4% 97.4% 97.4% 97.4%
MPPT Efficiency 99.9% 99.9% 99.9% 99.9% 99.9% 99.9%
Safety & Protection
DC Reverse-Polarity Protection Yes
DC Breaker Yes
DC/AC SPD (Surge Protection) Yes
Leakage Current Protection Yes
Insulation Impedance Detection Yes
Residual Current Protection Yes
Output Short Circuit Protection Yes
Battery Reverse Connection Protection Yes
General Parameters
Dimensions (L × W × H) 650 x 210 x 360 mm
Weight 29 kg
Operating Temperature -25°C to +60°C
Degree of Protection (IP Code) IP54
Cooling Concept Natural Convection
Topology Transformerless
Display LCD
Humidity 0-95% (Non-Condensing)
Communication Standard WiFi/GPRS/LAN (optional)
Warranty Standard 5 years; 7/10 years optional
BMS Communication CAN / RS485
Meter  Communication RS485
Certificates & Approvals
CQC, VDE-AR-N4105, IEC61727, IEC62116, VDE0124-AR-N0124, ENS0549, IEC62109, IEC62477
The range of output voltage and frequency may vary depending upon different grid codes.
Specifications are subject to change without advance notice.
 
Items 6.14kWh 12.28kWh 18.42kWh 24.56kWh
Nominal Capacity 6.14kWh 12.28kWh 18.42kWh 24.56kWh
Size (L × W × H)(mm) 650x210x410 650x210x820 650x210x1230 650x210x1640
Weight 69kg 138kg 207kg 276kg
Max Usable Capacity 5.53kWh 11.05kWh 16.58kWh 22.10kWh
Rated Discharge/Charge Current 7.2A 14.4A 21.6A 28.8A
Nominal Dis-/Charge Power 3.69kW 7.37kW 11.06kW 14.75kW
Peak Power (Only Discharge) 6.14kW for 3s 12.28kW for 3s 18.42kW for 3s 24.56kW for 3s
General Specifications
Battery Operation Voltage 448-568Vdc
Nominal Battery Voltage 512V
Max Battery Voltage 568V
Max Recommended DOD 90%
Operating Condition Indoor
Operating Temperature From -10~50℃
WiFi Frequency Range 2400MHz~2483MHz
Humidity <60%(No condensed water)
Pollution Degree 3
Over Voltage Category II
Cooling Type Natural cooling
Case Material Aluminium alloy
IP Rating IP 54
Efficiency 96%
Protective Class I
Max Number of Parallel 4
Warranty 10 years
Life Span >15 years
Communication CAN/ RS485
Battery Protection Over-current/Over-voltage/Short circuit/ Under-voltage/Over temperature
Hazardous Material Classification 9
Transportation UN 38.3
Certification & Safety Standard CE / UL1973 / IEC62619 / IEC 62477 / IEC 62040 / MSDS / UN38.3
Testing conditions based on temperature 25 C at the beg inning of life.
*Total Energy/Usable Energy measured under specific conditions trom Uhome 0.2C CC-CV

Hulp Nodig?